Reverse Osmosis Systems

If your water or chemical process must be extremely clean and Nanofiltration systems are not up to the task then you need one of ISC’s reverse osmosis systems. These systems use special membranes to reject metals, salts and organic impurities down to the molecular level. This RO water filtration process leaves your liquids with an extraordinarily high purity level and the confidence that your application will not be disrupted by impurities.

Our reverse osmosis water filtration system is designed to provide the commercial and industrial user with the most trouble free, cost effective and reliable form of water treatment available, by providing every option necessary for a successful installation. With several different options available ISC’s Systems can treat from 150 to 6,600 Gallons per day. However, larger units, along with accessory options such as mounting legs and water tanks, are available upon request.

 Reverse Osmosis Brochure

 Membrane Filter Brochure

Standard Features:

  • Powder coated steel frame
  • Inlet solenoid valve
  • 20” prefilter
  • Prefilter pressure gauge
  • Multistage centrifugal pump
  • Low-pressure protection with microprocessor auto reset
  • 2 ½” liquid filled pump pressure gauge
  • Stainless steel pressure vessel(s)
  • Product flow meter
  • Reject flow meter
  • Concentrate needle valve
  • Non metallic recycle needle valve
  • On / off toggle switch
  • Feed water and product water TDS monitor

Specifications:

Membrane Size: 4″ x 40″
Average membrane rejection: 98%
Feed water connection: 3/4″ NPTF
Prefilter: 20″
Product water connection: 5/8″ tubing OD
Reject water connection: 5/8″ tubing OD
Feed water pressure (minimum): 10 PSI
Electrical Requirement: 120 VAC 60 HZ

 Models:

R4X40-1 R4X40-2 R4X40-3
Maximum Productivity (gallons per day): 2,200 4,400 6,600
Recovery (user adjustable): 15 – 75% 25 – 75% 32 – 75%
Number of membranes: 1 2 3
Feed water required (maximum): 10 GPM 12 GPM 14 GPM
Drain required (maximum): 10 GPM 12 GPM 14 GPM
Motor horse power: 3/4 1 1-1/2
Electrical requirement: 15 amps 20 amps 25 amps
Dimensions W x D x H: 20 x 20 x 50 20 x 20 x 50 20 x 26 x 50
Shipping Weight (estimated lbs): 120 150 180

Standard Features for R-12 Wall-mounted Systems

  • Stainless steel frame
  • Automatic inlet valve
  • Pre-filter housing and cartridge, 10″
  • Procon pump (brass)
  • 1/2 HP motor
  • Liquid filled pump pressure gauge (2-1/2″)
  • Stainless steel pressure vessels
  • Needle valve for concentrate line
  • Needle valve for recycle line
  • Check valve for product water (stainless steel)
  • Product pressure switch with Auto/Off
  • Low-pressure shut-off with automatic restart

Specifications:

Product water & reject water connection (tubing): 3/8″
Feed water requirement (maximum): 2.4 GPM
Feed water pressure requirement (minimum): 10 PSIG
Drain requirement (maximum): 2.4 GPM
Electrical Requirement: 120 VAC 60 HZ
Amps: 8
Pump: 1/2 HP

 Models:

Item # GPD Recovery ( Adjustable) Membrane Size # of Membranes Feed Water Connection Typical Rejection Dimensions
R12-0150-1 150 15%-75% 2-1/2″x14″ 1 1/2″ NPT 98% 22″x32″x12″
R12-0150-2 150 15%-75% 2-1/2″x14″ 1 1/2″ NPT 98% 22″x32″x12″
R12-0150-3 150 15%-75% 2-1/2″x14″ 1 1/2″ NPT 98% 22″x32″x12″
R12-0250-1 250 15%-75% 2-1/2″x21″ 1 1/2″ NPT 98% 22″x32″x12″
R12-0250-2 250 15%-75% 2-1/2″x21″ 1 1/2″ NPT 98% 22″x32″x12″
R12-0250-3 250 15%-75% 2-1/2″x21″ 1 1/2″ NPT 98% 22″x32″x12″
R12-0600-1 600 15%-75% 2-1/2″x40″ 1 1/2″ NPT 98% 22″x52″x12″
R12-0600-2 600 15%-75% 2-1/2″x40″ 1 1/2″ NPT 98% 22″x52″x12″
R12-0600-3 600 15%-75% 2-1/2″x40″ 1 1/2″ NPT 98% 22″x52″x12″
R12-1200-1 1200 25%-75% 2-1/2″x40″ 2 1/2″ NPT 98% 22″x52″x12″
R12-1200-2 1200 25%-75% 2-1/2″x40″ 2 1/2″ NPT 0.98 22″x52″x12″
R12-1200-3 1200 25%-75% 2-1/2″x40″ 2 1/2″ NPT 0.98 22″x52″x12″

Standard Features for R-13 Compact Wall Mount RO

  • Powder coated steel frames
  • Inlet solenoid valve
  • Pre-filter
  • 1/2 HP motor
  • Brass pump
  • Liquid filled pre-filter pressure gauge
  • 2 1/2” liquid filled pump pressure gauge
  • Product water & reject water flow meters
  • High pressure, non-metallic membrane housings
  • SS needle valves for concentrate and recycle lines
  • Stainless steel product water check valve
  • On / off toggle switch
  • Low-pressure shut-off with auto restart
  • Feed water and product water TDS monitor

Specifications:

Feed water connection: 3/4″ NPTF
Product water connection: 3/8” Tubing OD
Reject water connection: 3/8” Tubing OD
Feed water required (max.) 2.4 GPM
Feed water required (min.) 10 PSI
Drain required (max.) 2.4 GPM
Electrical requirements: 120 VAC 60 Hz
Amps: 8
Pump (H.P.): 1/2

 Models:

R13-0250 R13-0600 R13-1200
Maximum Productivity (gallons per day): 250 600 1,200
Average membrane rejection rate: 98% 98% 98%
Recovery (adjustable): 8 – 75 % 17 –75% 34 – 75 %
Membrane size: 3” x 10” 3” x 20” 3” x 20”
Number of membranes: 1 1 2
Pre-filter (system ships with one 5 micron cartridge): 10″ 20″ 20″
Dimensions, approximate (W x H x D): 26″ x 26″ x 9″  26″ x 36″ x 9″  26″ x 36″ x 9″
Shipping Weight, estimated (lbs.): 50 60 75